Wholesale Air Compressor Filter Element 170837000 Industrial Air Filter
Product Description
Tips:Because there are more 100,000 types of air compressor filter elements, there may be no way to show one by one on the website, please email or phone us if you need it.
The main reason for the hot air filter of screw air compressor is that the air filter plays the role of compressed air during operation, resulting in an increase in its temperature. In addition, the air filter's working environment, cooling system and lubrication system and other factors will also affect its temperature .
Specific reasons include:
Heat sink blockage : heat sink blockage will lead to reduced cooling effect, which will cause the air filter temperature increase .
Cooling fan does not work : The cooling fan is a key component for forced heat dissipation. If the fan does not work or is damaged, the heat dissipation effect will be affected and the temperature will increase .
Insufficient lubricating oil or oil quality : insufficient lubricating oil will lead to decreased lubrication effect, increase friction and temperature, and then affect the temperature of the air filter .
Oil filter blockage : oil filter blockage will affect the oil circulation, lead to the decrease of lubrication effect, and then cause the temperature to rise .
Environmental factors : such as the ambient temperature is too high, poor ventilation, etc., will affect the heat dissipation effect, resulting in the air filter temperature rise .
Equipment host problems : such as bearing wear, leakage in the rotor, etc., increase the operating resistance and heat, resulting in the air filter temperature rise .
In order to solve these problems, the following measures can be taken:
Regularly clean the radiator : Use an air gun or high pressure water gun to clean the dust and carbon deposits on the radiator to ensure the heat dissipation .
Check the cooling fan : ensure that the cooling fan is working properly, repair or replace if necessary .
Check the amount of lubricating oil : ensure that the amount of lubricating oil is sufficient, and timely replace the lubricating oil and oil filter .
Improve the working environment : ensure that the working environment is well ventilated, the temperature is appropriate, avoid overheating .
Regularly maintain the host : Periodically check and maintain the host to ensure its normal running.